Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Clinical and Experimental Obstetrics and Gynecology ; 50(2) (no pagination), 2023.
Article in English | EMBASE | ID: covidwho-2301146

ABSTRACT

Background: Patients undergoing an interventional radiology procedure report some degree of anxiety. Therefore, procedure-related anxiety needs to be managed. The aim of our study was to investigate patient satisfaction with monitored anesthesia care (MAC) for uterine artery embolization (UAE)-related procedural anxiety in symptomatic uterine fibroids or adenomyosis. Method(s): Between May 2021 and June 2022, 36 patients with symptomatic fibroids or adenomyosis underwent UAE with MAC. Follow-up evaluations consisted of clinical symptoms, degree of satisfaction with MAC in UAE, and complications. Result(s): MAC in UAE was successfully performed in all patients. UAE significantly reduced patients' complaints such as bleeding and pain: the scores for bleeding and pain were significantly reduced after 3 months of UAE compared with those before UAE, indicating the effectiveness of UAE. The mean score of satisfaction with MAC in UAE was 4.3 points, meaning that 94.4% of women were satisfied or very satisfied. No major complications were observed. Conclusion(s): MAC in UAE for symptomatic uterine fibroids or adenomyosis can be emotionally effective and safe for patients who are anxious about the procedure.Copyright © 2023 The Author(s).

2.
Journal of Pharmaceutical Negative Results ; 13:7299-7305, 2022.
Article in English | EMBASE | ID: covidwho-2227834

ABSTRACT

Introduction: The bispectral index monitors the unawareness component of balanced anaesthesia and gives us the depth of Anesthesia.It reflects the response of the brain to a variety of hypnotic and inhaled anaesthesia agents. The aim of this study was to see the effect of different MAC values of isoflurane on the bispectral index and hemodynamic variations at different MAC values. Material(s) and Method(s): This prospective study was conducted on 20 patients at tertiary care center for 6 months. After induction of Anesthesia, following parameters were recorded: noninvasive blood pressure measurement, heart rate, oxygen saturation, ETCo2 and BIS values. The BIS was continuously monitored and when the MAC values of isoflurane were 0.5, 0.7, 1, 1.2 and 1.5 corresponding BIS values and all the other haemodynamic parameters were noted. Result(s): In 11 patients out of 20 patients satisfactory BIS of 40-60 was achieved at MAC 0.5. In 16 out of 20 patients satisfactory BIS 40-60 was achieved at 0.7 MAC. In all the 20 patients satisfactory BIS was achieved at 1 MAC.In 2 out of 20 patients we couldn't proceed beyond 1.0 MAC because of the fall in MAP to <65mm of Hg. In 4 out of 20 patients we couldn't proceed beyond 1.2MAC because of the fall in MAP to <65mm of Hg. Conclusion(s): Isoflurane produced satisfactory BIS of 40-60 in 16 patients at 0.7 MAC and in all the 20 patients at 1 MAC.Use of BIS in our study helped in better titration of Isoflurane according to patient's individual needs thereby we avoided light plane of anaesthesia or deep hypnosis and the adverse effects associated with it. Copyright © 2022 Wolters Kluwer Medknow Publications. All rights reserved.

SELECTION OF CITATIONS
SEARCH DETAIL